• In saldo!
  • -5%

UNMNGD WT IND CTRL SWITCH 4P+1F SC 12

Riferimento: DVS-005W01-SC01

332,65 €
316,02 € Risparmia 5%

Sconti per volumi

Quantità Prezzo Unitario Prezzo Lotto Risparmi
3 € 306.04 € 918.11 Fino a 79.84
5 € 299.38 € 1496.92 Fino a 166.32
10 € 282.75 € 2827.53 Fino a 498.98
Quantità

100% pagamenti sicuri
 

 

DVS-005W01-SC01

     
 
Unmanaged Switches - DVS-005W01-SC01
 
     
 
  • Features & Benefits
  •  
    12 to 48 VDC redundant terminal block power input
    Auto warning by relay output for link-down and power failure
    Compatible with various industrial protocols of EtherNet/IP, Profinet, CC-LINK IE and DNP 3.0
     
     
         
     
    Specifications
     
     
      Technology
     
    Standard Compliance
    IEEE 802.3 10Base-T
    IEEE 802.3u 100Base-T(X) and 100Base-FX
    IEEE 802.3x Flow Control
    Store and Forward
    IEEE 802.3x Flow control in full duplex, back-pressure flow control in half duplex
      Interface
     
    Fast Ethernet Ports
    RJ45 Ports: 4 10/100Base-T(X), auto MDI/MDI-X, auto negotiation
    Fiber Optic Ports: 1 100Base-FX (SC connector), SingleMode – 30km
    Alarm Contacts(DO)
    1 relay output
    Carry current 5 A@24VDC
      Performance and Scalability
     
    Switching Capacity: 1Gbps, Wired speed, Non-blocking switching fabric
    Forwarding Rate: 1.5Mpps
    MAC Address Table: 1K
    Packet Buffer Memory: 512K bits
      Power Requirements
     
    Input Voltage: 2 sets, 12 to 48 VDC redundant terminal block input
    Input Current: Max. 0.24A
    Overload Current Protection: Present, Max. input current 3A
    Reverse Polarity Protection: Present
    Buffer Time: Min. 13ms at 24VDC
    06/060308/dot_line.jpg
      Physical
     
    Housing: IP40 aluminum metal case
    Dimensions: 145.3 mm(H) × 45 mm(W) × 108.7 mm (D)
    Weight: 300g
    Installation: Industrial DIN-Rail and wall mounting
      Environmental Limits
     
    Operating Temperature: -40℃ to 75℃(-40℉ to 167℉)
    Storage Temperature: -40℃ to 85℃(-40℉ to 185℉)
    Ambient Relative Humidity: 5% to 95%(non-condensing)
      Approvals
     
    Safety: UL 508, EN 60950-1, IEC 61131-2
    EMI: FCC 47 CFR Part 15 Subpart B Class B, IEC 61000-6-4, EN 55022
    EMS: IEC 61000-6-2
    Environmental Type Tests
    Cold Temperature: IEC 60068-2-1
    Dry Heat: IEC 60068-2-2
    Humidity: IEC 60068-2-30
    Shock: IEC 60255-21-2
    Freefall: IEC 60068-2-32
    Vibration: IEC 60068-2-6
    Hi-Pot: 1.5KV
    DVS-005W01-SC01

    Scheda tecnica

    Operating Temperature
    -40C to 75C
    DI
    2
    10/100 Base-T(x)
    4
    100Base-FX
    1.0

    Riferimenti specifici

    16 altri prodotti della stessa categoria: