• In saldo!
  • -5%

UNMNGD WT IND CTRL SWITCH 6P+2F MC 12

Riferimento: DVS-008W01-MC02

406,70 €
386,37 € Risparmia 5%

Sconti per volumi

Quantità Prezzo Unitario Prezzo Lotto Risparmi
3 € 374.16 € 1122.49 Fino a 97.61
5 € 366.03 € 1830.15 Fino a 203.35
10 € 345.69 € 3456.95 Fino a 610.05
Quantità

100% pagamenti sicuri
 

 

DVS-008W01-MC02

     
 
Unmanaged Switches - DVS-008W01-MC02
 
     
 
 
Supports IEEE 802.1p based QoS for packet forwarding precedence
Built-in Broadcast Storm Protection
Transparent transmission of VLAN tagged packets
12 to 48 VDC redundant terminal block power input
Auto warning by relay output for link-down and power failure
Compatible with various industrial protocols of EtherNet/IP, Profinet, CC-LINK IE and DNP 3.0
 
 
     
 
Specifications
 
 
  Technology
 
Standard Compliance
IEEE 802.3 10Base-T
IEEE 802.3u 100Base-T(X) and 100Base-FX
IEEE 802.3x Flow Control
IEEE 802.1p Class of Service, Priority Protocols
Processing Type
Store and Forward
IEEE 802.3x Flow control in full duplex, back-pressure flow control in half duplex
  Interface
 
Fast Ethernet Ports
RJ45 Ports: 6 10/100Base-T(X), auto MDI/MDI-X, auto negotiation
Fiber Optic Ports: 2 100Base-FX (SC connector), MultiMode – 5km
Alarm Contacts(DO)
1 relay output
Carry current 5 A@24VDC
  Performance and Scalability
 
Switching Capacity: 1.6Gbps, Wired speed, Non-blocking switching fabric
Forwarding Rate: 2.4Mpps
MAC Address Table: 8K
Packet Buffer Memory: 1M bits
Broadcast Storm Protection: Default enabled
Transparent Forwarding VLAN Tagged Packets: Default enabled
IEEE 802.1p based QoS: Default enabled
  Power Requirements
 
Input Voltage: 2 sets, 12 to 48 VDC redundant terminal block input
Input Current: Max. 0.45A
Overload Current Protection: Present, Max. input current 3A
Reverse Polarity Protection: Present
Buffer Time: Min. 13ms at 24VDC
  Physical
 
Housing: IP40 aluminum metal case
Dimensions: 145.3 mm(H) × 75 mm(W) × 108.7 mm (D)
Weight: 430g
Installation: Industrial DIN-Rail and wall mounting
  Environmental Limits
 
Operating Temperature: -40℃ to 75℃(-40℉ to 167℉)
Storage Temperature: -40℃ to 85℃(-40℉ to 185℉)
Ambient Relative Humidity: 5% to 95%(non-condensing)
  Approvals
 
Safety: UL 508, EN 60950-1, IEC 61131-2
EMI: FCC 47 CFR Part 15 Subpart B Class B, IEC 61000-6-4, EN 55022
EMS: IEC 61000-6-2
Environmental Type Tests
Cold Temperature: IEC 60068-2-1
Dry Heat: IEC 60068-2-2
Humidity: IEC 60068-2-30
Shock: IEC 60255-21-2
Freefall: IEC 60068-2-32
Vibration: IEC 60068-2-6
Hi-Pot: 1.5KV
DVS-008W01-MC02

Scheda tecnica

Operating Temperature
-40C to 75C
DI
1.0
DO (Relay)
2
10/100 Base-T(x)
6
100Base-FX
2.0

Riferimenti specifici

16 altri prodotti della stessa categoria: