Features & Benefits
|
| |
 |
Data acquisition equipment connected to cloud servers. |
 |
Supports a two-way data collection channel between the device and the cloud |
 |
Sets up a secure tunnel between the user and the remote device via the cloud server, without the need of additional VPN servers |
 |
Supports MODBUS TCP and MODBUS RTU/ASCII protocols |
 |
Using UMTS/HSPA+ 3G technology, supports a wide range of bands (800/850, 900, AWS1700, 1900, 2100 MHz), downward compatible with GSM / GPRS / EDGE 2G network |
 |
HSPA+ data transmission rate up to 21.6 Mbps (downlink) / 5.76Mbps (uplink) |
 |
Automatic APN parameter matching and connection redial |
 |
Various peripheral interfaces include RS-485, RS-232 and LAN ports |
 |
Built-in RTC and supports NTP time synchronization over a network |
 |
Firewall functions: Stateful Packet Inspection (SPI), Prevent Denial of Service (DoS) attacks, NAT, port triggering, port mapping, IP address filter, MAC address filter, URL filter |
 |
Supports TCP/IP, UDP, ICMP, DHCP, HTTP, DNS and SSH protocols |
 |
Scheduled jobs are available |
 |
Device configurations can be exported and imported. |
 |
Network data flow statistics |
 |
Networking failure diagnostics |
 |
Device and PLC interlocking |
 |
Custom alarm conditions with email alerts |
 |
Supports Android and iOS devices on-line monitoring |
 |
|
|
|
|
|
|
| |
|
|
| |
|
|
| |
| |
TECHNOLOGY |
| |
|
 |
GSM/GPRS/EDGE/UMTS/HSPA+ |
|
|
 |
IEEE 802.3 10Base-T |
|
|
 |
IEEE 802.3u 100Base-T(X) |
|
|
| |
INTERFACE |
| |
|
 |
GSM/GPRS/EDGE/UMTS/HSPA+ |
|
|
 |
1 2.5dBi omni-directional, SMA(male) connector, 3 meters cable with magnetic stand |
|
|
 |
RJ45 Ports: 1 10/100Base-T(X), auto MDI/MDI-X, auto negotiation |
|
|
 |
Serial Ports: 1 RS-232(DB9 male), 1 RS-485( DB9 female), 15KV isolation protection |
|
|
 |
Baud Rate: 2400bps to 115200bps |
|
|
 |
Data Bits: 7, 8 |
|
|
 |
Parity: None, Even, Odd |
|
|
 |
Stop Bits: 1, 2 |
|
|
 |
Flow Control: RTS/CTS(RS-232 only), XON/XOFF |
|
|
 |
RS-232: TxD, RxD, RTS, CTS, GND |
|
|
 |
RS-485: D+, D-, GND |
|
|
 |
Device: PWR, SD, Ready, 3G, Signal Strength |
|
|
 |
RJ45 Ports: LAN |
|
|
 |
Serial Ports: RS-232 RX, RS-232 TX, RS-485 RX, RS-485 TX |
|
|
 |
1set |
|
|
| |
3G RF |
| |
|
 |
UMTS/HSPA+: 800 / 850, 900, AWS1700, 1900, 2100 MHz |
|
|
 |
UMTS/HSPA+(CN model): 900, 2100 MHz |
|
|
 |
GSM/GPRS/EDGE: 850 / 900 / 1800 / 1900 MHz |
|
|
| |
MANAGEMENT |
| |
|
 |
DIACloud |
|
|
 |
SSH, DNS, HTTP, TFTP, DHCP Server/Client, Telnet, Syslog, MODBUS TCP, NTP, MODBUS RTU/ASCII |
|
|
 |
MAC/IP/URL filtering, SSH, SPI, Prevent denial of service (DoS) attacks, Port triggering, Port mapping |
|
|
 |
Windows XP, Windows Vista (32/64 bits), Windows 7 (32/64 bits) |
|
|
 |
Web Browser, DIACom, Android APP, iOS APP |
|
|
| |
POWER REQUIREMENTS |
| |
|
 |
Input Voltage: 12 to 48VDC, 3 pin terminal block input |
|
|
 |
Input Current : 1A Max. |
|
|
 |
Overload Current Protection: Present, Max. Input current 1.5A |
|
|
 |
Reverse Polarity Protection: Not Present |
|
|
| |
PHYSICAL |
| |
|
 |
Housing: IP30 metal case |
|
|
 |
Dimensions: 111 mm(H) x 77 mm(W) x 26 mm (D) |
|
|
 |
Weight: 196g |
|
|
 |
Installation: Wall mounting |
|
|
| |
ENVIRONMENTAL LIMITS |
| |
|
 |
Operating Temperature : -20℃ to 70℃(-4℉ to 158℉) |
|
|
 |
Storage Temperature: -40℃ to 85℃(-40℉ to 185℉) |
|
|
 |
Ambient Relative Humidity: 5% to 95%(non-condensing) |
|
|
| |
APPROVALS |
| |
|
 |
Safety: UL 60950-1, EN 60950-1(DX-2100RW-WW certificated) |
|
|
 |
EMI: FCC 47 CFR Part 15 Subpart B Class A, EN 55022, EN 301 489-1/7/24 (DX-2100RW-WW certified) |
|
|
 |
EMS( EN 301 489-1/7/24, EN 55024): IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8 (DX-2100RW-WW certified) |
|
|
 |
RF: EN 301 511, EN301 908-1; FCC Part 22H, 24E, 27(DX-2100RW-WW certificated) |
|
|
|
|
|
|