Features & Benefits
|
|
|
Data acquisition equipment connected to cloud servers. |
|
Supports a two-way data collection channel between the device and the cloud |
|
Sets up a secure tunnel between the user and the remote device via the cloud server, without the need of additional VPN servers |
|
Supports MODBUS TCP and MODBUS RTU/ASCII protocols |
|
Flexible connection method over WAN ports, e.g. static IP, DHCP client and more |
|
Various peripheral interfaces include RS-485, RS-232 and 4 LAN ports |
|
Built-in RTC and supports NTP time synchronization over a network |
|
Firewall functions: Stateful Packet Inspection (SPI), Prevent Denial of Service (DoS) attacks, NAT, port triggering, port mapping, IP address filter, MAC address filter, URL filter |
|
Supports TCP/IP, UDP, ICMP, DHCP, HTTP, DNS and SSH protocols |
|
Scheduled jobs are available |
|
Device configurations can be exported and imported. |
|
Network data flow statistics |
|
Networking failure diagnostics |
|
Device and PLC interlocking |
|
Custom alarm conditions with email alerts |
|
Supports Android and iOS devices on-line monitoring |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
TECHNOLOGY |
|
|
|
IEEE 802.3 10Base-T |
|
|
|
IEEE 802.3u 100Base-T(X) |
|
|
|
INTERFACE |
|
|
|
RJ45 Ports: |
|
|
WAN: 1 10/100Base-T(X), auto MDI/MDI-X, auto negotiation |
|
|
LAN: 4 10/100Base-T(X), auto MDI/MDI-X, auto negotiation |
|
|
|
Serial Ports : 1 RS-232(DB9 male), 1 RS-485( Terminal block), 15KV isolation protection |
|
|
|
Baud Rate: 2400bps to 115200bps |
|
|
|
Data Bits: 7, 8 |
|
|
|
Parity: None, Even, Odd |
|
|
|
Stop Bits: 1, 2 |
|
|
|
Flow Control: RTS/CTS(RS-232 only), XON/XOFF |
|
|
|
RS-232: TxD, RxD, RTS, CTS, GND |
|
|
|
RS-485: D+, D-, GND |
|
|
|
Device: PWR, SD, Ready |
|
|
|
RJ45 Ports: 100M, LINK/ACT |
|
|
|
Serial Ports: RS-232, RS-485 |
|
|
|
1set |
|
|
|
MANAGEMENT |
|
|
|
DIACloud |
|
|
|
SSH, DNS, HTTP, TFTP, DHCP Server/Client, Telnet, Syslog, MODBUS TCP, NTP, MODBUS RTU/ASCII |
|
|
|
MAC/IP/URL filtering, SSH, SPI, Prevent denial of service (DoS) attacks, Port triggering, Port mapping |
|
|
|
Windows XP, Windows Vista (32/64 bits), Windows 7 (32/64 bits) |
|
|
|
Web Browser, DIACom, Android APP, iOS APP |
|
|
|
POWER REQUIREMENTS |
|
|
|
Input Voltage: 9to 40VDC, 2 pin terminal block input |
|
|
|
Input Current: 0.53A Max. |
|
|
|
Overload Current Protection: Present, Max. Input current 1.5A |
|
|
|
Reverse Polarity Protection: Not Present |
|
|
|
PHYSICAL |
|
|
|
Housing: IP30 metal case |
|
|
|
Dimensions: 145.3 mm(H) x 45 mm(W) x 112.3 mm (D) |
|
|
|
Weight: 308g |
|
|
|
Installation: Industrial DIN-Rail and Wall mounting |
|
|
|
ENVIRONMENTAL LIMITS |
|
|
|
Operating Temperature : -20℃ to 70℃(-4℉ to 158℉) |
|
|
|
Storage Temperature: -40℃ to 85℃(-40℉ to 185℉) |
|
|
|
Ambient Relative Humidity: 5% to 95%(non-condensing) |
|
|
|
APPROVALS |
|
|
|
Safety: UL 60950-1, EN 60950-1 |
|
|
|
EMI: FCC 47 CFR Part 15 Subpart B Class A, EN 55022 |
|
|
|
EMS( EN 55024): IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8 |
|
|
|
|
|
|