• -5%

PROGRAMMABLE LOGIC CTRL 10MC DC 6

Reference: DVP10MC11T

€774.94
€736.19 Save 5%

Volume discounts

Quantity Prezzo Unitario Prezzo Lotto You Save
3 € 712.94 € 2138.83 Up to 185.99
5 € 697.45 € 3487.23 Up to 387.47
10 € 658.70 € 6586.99 Up to 1162.41
Quantity

100% secure payments
 

Delta DVP10MC11T Ethernet RS232 RS485 CAN 8DI 4DO Module

*Up to 16 axes can be controlled through high-speed CANopen communication 
*Provides E-Cam (2048 points), rotary cut and flying shear applications 
*Compatible with DVP-S series left and right side modules for flexible applications

 

CANopen Accessories

Model name

Spec.

Features

TAP-CN01/02/03

Distribution Boxes

Built-in terminal resistor 12 Ohm

TAP-CB01/02/03/05/10/20

CANopen communication cables

Standard CANopen Cables

TAP-TR01

Terminal Resistor

Terminal Resistor 120 Ohm

 

Specifications

*Built-in 12 I/O points (8 sets of high-speed pulse inputs for interrupt function and 4 sets of high-speed outputs) 
*Max. 480 I/O points 
*Program capacity?Ladder 16k steps / Motion 1Mbyte 
*Built-in Ethernet, RS-232 and RS-485 communication port and standard MODBUS ASCII/RTU communication protocol 
*Flexible industrial network applications 
(provides DeviceNet Master/Slave, CANopen Master/Slave, PROFIBUS-DP Slave and many more modules) 
*Provides standard CANopen communication cables, terminal resistors, distribution boxes and related accessories. Wiring is simple and easy. 
*Synchronously controls 4 axes in 2ms and 8 axes in 4ms 
*Compatible with G-Code 
*Supports PLCopen standard function blocks for motion control, enhancing program editing efficiency

 

Power Supply

 

Power supply voltage

24 VDC (-15 to +20%)

Power supply fuse

3 A/30 VDC, Polyswitch

Insulation voltage

500 VDC (Secondary-PE)

Power consumption

8 W Max.

Shock/vibration

immunity

Standards: IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC

68-2-27 (TEST Ea)

Noise immunity

ESD (IEC 61131-2, IEC 61000-4-2): 8 kV Air Discharge

EFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2 kV, Digital I/O: 1 kV, Analog & Communication I/O: 1 kV

Damped-Oscillatory Wave: Power Line: 1 kV, Digital I/O: 1 kV RS (IEC 61131-2, IEC 61000-4-3): 26 MHz ~ 1GHz, 10 V/m

Ambiance

Operation: 0 to 55°C (temperature), 50 to 95% (humidity), pollution

degree 2

Storage: -25 to 70°C (temperature), 5 to 95% (humidity)

Weight

Approx. 240g

 

I/O Specifications

 

I/O channels

8 input channels, 4 output channels

I/O channel types

8 high-speed digital input channels, 4 high-speed digital output channels

I/O terminals

Input terminals: I0, I1, I2, I3, I4, I5, I6, I7

Output terminals: Q0, Q1, Q2, Q3

Common terminal for input points

Wiring terminal S/S (for connecting to the positive or negative pole of the power supply)

Input types

Sink or Source

I/O delay time

Input: 2.5 us (OFFàON), 5 us (ONàOFF)

Output: 2 us (OFFàON), 3 us (ONàOFF)

Input signal current

24 VDC, 5 mA

Max. I/O cable length

Shielded: 500m; Not shielded: 300m

Power supply for output points

24 VDC (-15 to +20%) #1

Max. load

Resistive load: 0.5 A/1 point (2A/ZP)

Conductive load: 13 W (30 VDC)

Light bulb load: 2.5 W (30 VDC)

#1: UP and ZP must use external auxiliary 24 VDC power supply (-15 to 20%).

DVP10MC11T

Data sheet

Type
CANopen
Input
8
Output
4

Specific References

16 other products in the same category: